The difference between RDF and SRF is a specification, and that specification decides whether you sell a fuel or pay to dispose of a waste. This guide covers the EN 15359 three-digit classification, why chlorine is the binding constraint, production line design and achievable substitution rates in cement kilns.

By Charmaine Frost, Director and Landfill Gas Specialist

Processed waste fraction stockpiled for fuel production

In short

Refuse-derived fuel is the generic term for fuel produced from waste. Solid recovered fuel is RDF produced to the EN 15359 specification, now transitioned into international standard ISO 21640 [1]. EN 15359 classifies SRF with a three-digit code covering net calorific value as the economic parameter, chlorine as the technical parameter and mercury as the environmental parameter, each graded Class 1 to 5 [1]. Class 1 requires NCV of at least 25 MJ/kg, chlorine at or below 0.2 per cent and mercury at or below 0.02 mg/MJ median [1]. Thermal substitution rates reach 80 to 100 per cent in a cement calciner but only 50 to 60 per cent in the kiln burner [2].


Key facts

  • EN 15359 classifies SRF with a three-digit code for net calorific value, chlorine and mercury, each graded Class 1 to 5, and has transitioned into international standard ISO 21640 [1].
  • Class 1 requires NCV of at least 25 MJ/kg, chlorine at or below 0.2 per cent and mercury at or below 0.02 mg/MJ median and 0.04 mg/MJ at the 80th percentile [1].
  • Class 5, the lowest acceptable tier, permits NCV of at least 3 MJ/kg, chlorine up to 3.00 per cent and mercury up to 0.50 mg/MJ median [1].
  • Mercury class uses both the median and the 80th percentile value, accounting statistically for sudden mercury spikes in the waste stream [1].
  • Maximum thermal substitution rate through RDF is 80 to 100 per cent in the cement calciner but 50 to 60 per cent in the kiln burner [2].
  • Chlorine volatilises at kiln temperature to form alkali chlorides, causing high-temperature corrosion of heat exchanger tubes and preheater cyclone blockages [1].
  • RDF from municipal solid waste typically records lower heating values averaging 14 to 22 MJ/kg, classified NCV II to IV, chlorine II and mercury I [3].
  • Dubai’s Warsan plant processes up to 6,000 tonnes per day of residual waste, indicating the scale of thermal offtake now established regionally [4].

Plain English — the essentials, in everyday language

Plain English

RDF versus SRF

Refuse-derived fuel is any fuel made from waste. It is a description, not a standard.

Solid recovered fuel is RDF made to a published specification, EN 15359, which has now become the international standard ISO 21640 [1].

That difference is commercial, not semantic. A cement plant will contract for SRF against a class. Unspecified RDF has far fewer buyers and often attracts a gate fee instead of earning revenue.

The three-digit code

EN 15359 grades SRF on three properties, each from Class 1 as best to Class 5 as lowest acceptable [1].

The first digit is net calorific value. This is the economic parameter, because it determines how much coal or petcoke the fuel replaces.

The second digit is chlorine. This is the technical parameter, and it is usually the one that causes problems.

The third digit is mercury. This is the environmental parameter.

So SRF Class 3-2-2 means NCV of at least 15 MJ/kg, chlorine at or below 0.6 per cent (dry basis) and mercury at or below 0.03 mg/MJ median and 0.06 mg/MJ at the 80th percentile [1].

The class limits

Net calorific value, mean as received [1]:

  • Class 1: at least 25 MJ/kg.
  • Class 2: at least 20 MJ/kg.
  • Class 3: at least 15 MJ/kg.
  • Class 4: at least 10 MJ/kg.
  • Class 5: at least 3 MJ/kg.

Chlorine, mean dry basis [1]:

  • Class 1: 0.2 per cent or less, rising through 0.6, 1.0 and 1.5 to Class 5 at 3.0 per cent.

Mercury, median and 80th percentile [1]:

  • Class 1: 0.02 and 0.04 mg/MJ, rising to Class 5 at 0.50 and 1.00 mg/MJ.

Why chlorine matters so much

Chlorine is the constraint that stops most projects, and it is worth understanding why.

At kiln temperature, chlorine volatilises and forms alkali chlorides with sodium and potassium [1].

Those chlorides attack heat exchanger tubes, causing high-temperature corrosion. They also condense in the preheater cyclones, where material sticks and eventually blocks the tower [1].

A blocked preheater means an unplanned kiln shutdown. That is why cement plants set hard chlorine limits and enforce them.

Most chlorine comes from PVC and from salt in food residues.

Why mercury is measured differently

Mercury uses both the median and the 80th percentile, rather than a simple mean [1].

That is deliberate. Mercury arrives in spikes, typically from a single discarded item, rather than spread evenly through the load. A mean would hide those spikes; the 80th percentile catches them.

How RDF is produced

The production line is a material recovery facility optimised for fuel rather than recyclables.

Bag opening and primary shredding come first. Then screening to remove the fines, which are mostly grit, glass and organics that dilute calorific value.

Magnets and eddy current separators remove metals, which have no calorific value and damage equipment.

Air classification or ballistic separation removes heavy inert material and concentrates the light, high-calorific fraction.

Drying may follow, often biodrying, to reduce moisture and raise calorific value.

Finally secondary shredding to a defined particle size, and optionally pelletising.

Substitution rates

This is the number cement plants care about, and it differs by injection point [2].

In the calciner, thermal substitution reaches 80 to 100 per cent.

In the main kiln burner, it is limited to 50 to 60 per cent.

The calciner runs cooler and is more tolerant. The main burner needs a hotter, faster-burning, finer fuel for flame stability and clinker quality.

What real RDF actually achieves

Field studies of RDF from municipal solid waste report lower heating values averaging 14 to 22 MJ/kg, classifying as NCV II to IV, chlorine II and mercury I [3].

So typical municipal RDF sits in the middle of the NCV range, does reasonably on chlorine, and performs well on mercury.

Where it goes in the Gulf

Cement production is substantial across the GCC, which provides a natural offtake.

Dubai’s Warsan plant now takes up to 6,000 tonnes a day of residual waste [4], and Abu Dhabi’s first waste-to-energy plant, at 900,000 tonnes a year, is due in 2027 [5].


Professional layer — engineering, operations & compliance detail (click to expand)

Professional

Standard framework

EN 15359 classifies solid recovered fuel using a three-digit classification code, each digit representing a class performance tier from Class 1 as the highest premium tier to Class 5 as the lowest acceptable tier, across three critical fuel vectors described as economic, technical and environmental [1].

The standard has been transitioned into international standard ISO 21640 to establish a unified global framework, and both compliance systems share the same core classification logic and three-digit performance code [1].

The full limit matrix [1]:

  • Class 1: NCV at least 25 MJ/kg, chlorine at or below 0.2 per cent, mercury at or below 0.02 median and 0.04 mg/MJ at the 80th percentile.
  • Class 2: NCV at least 20 MJ/kg, chlorine at or below 0.6 per cent, mercury 0.03 and 0.06 mg/MJ.
  • Class 3: NCV at least 15 MJ/kg, chlorine at or below 1.0 per cent, mercury 0.08 and 0.16 mg/MJ.
  • Class 4: NCV at least 10 MJ/kg, chlorine at or below 1.5 per cent, mercury 0.15 and 0.30 mg/MJ.
  • Class 5: NCV at least 3 MJ/kg, chlorine at or below 3.00 per cent, mercury 0.50 and 1.00 mg/MJ.

Note the differing statistical bases. NCV uses the mean on an as-received basis; chlorine uses the mean on a dry basis; mercury uses both median and 80th percentile [1]. A specification that does not state the basis is not enforceable.

Net calorific value as the economic parameter

The NCV tier determines the direct substitution rate of fossil fuels, whether coal or petroleum coke, within the calciner or boiler [1].

The as-received basis matters commercially because moisture is transported and paid for but contributes no energy. A fuel at 20 MJ/kg dry and 30 per cent moisture delivers materially less than 20 MJ/kg to the burner, and the difference is borne by the buyer unless the contract specifies as-received.

Field data provides the realistic range. RDF produced from municipal solid waste recorded average lower heating values of 14 to 22 MJ/kg, within the limits for thermal application, and classified as NCV II to IV [3].

Feedstock fraction drives the achievable class. Segregated high-calorific fractions perform far better than mixed waste: analysis of individual components found material at 29.74 MJ/kg reaching Class 1, textiles reaching Class 2, and empty fruit bunch biomass at 15.09 MJ/kg falling lower [6].

Chlorine as the technical constraint

Chlorine is the most critical technical constraint in co-processing [1].

The mechanism is specific. At high temperature inside cement kilns or waste-to-energy boilers, chlorine volatilises and forms volatile alkali chlorides, principally sodium chloride and potassium chloride. These cause severe high-temperature corrosion on heat exchanger tubes, and cause preheater cyclone blockages through material sticking [1].

The operational consequence of a preheater blockage is an unplanned kiln stop, which in cement production is expensive enough that plants enforce chlorine limits rigidly regardless of the commercial attractiveness of the fuel.

Chlorine sources are principally PVC and chloride salts from food residues. PVC removal requires targeted separation upstream, which mixed-waste sorting performs imperfectly because PVC is spectrally identifiable by near-infrared but present in irregular forms.

Some kilns operate a chlorine bypass, extracting a portion of kiln gas to remove the chloride circulation. That permits higher chlorine input but adds capital cost and generates a bypass dust requiring disposal.

Field-produced municipal RDF typically achieves chlorine Class II [3], meaning at or below 0.6 per cent; acceptability depends on the individual kiln’s chlorine balance and whether a bypass is fitted.

Mercury as the environmental parameter

Unlike NCV and chlorine which rely on mean values, EN 15359 determines the mercury class using both the median value and the 80th percentile value, a statistical approach accounting for sudden mercury spikes in the waste stream [1].

Class 1 restricts mercury to at or below 0.02 mg/MJ while Class 3 permits up to 0.08 mg/MJ [1].

The rationale is that mercury in municipal waste arrives discretely, from fluorescent tubes, batteries, thermostats and dental amalgam, rather than being distributed homogeneously. Mean values mask this; percentile reporting exposes it.

Municipal RDF generally performs well on this parameter, classifying at mercury Class I in field studies [3], because mercury-bearing items are removed by separate collection streams before the residual fraction is processed.

Production line design

An RDF or SRF production line is a mechanical treatment plant configured to concentrate calorific value rather than to recover materials.

A representative sequence:

  • Reception and bag opening.
  • Primary shredding to approximately 300 mm.
  • Trommel or star screening to remove a fines fraction typically below 40 to 80 mm, which carries grit, glass and organics that depress calorific value and raise ash.
  • Overband magnet for ferrous removal.
  • Eddy current separation for non-ferrous removal.
  • Air classification or ballistic separation to remove heavy inert material and concentrate the light two-dimensional fraction.
  • Optional near-infrared sorting for PVC removal where chlorine class must be improved.
  • Drying, commonly biodrying using the exothermic heat of partial aerobic decomposition.
  • Secondary shredding to specification particle size.
  • Optional densification by pelletising or briquetting.

Particle size specification is set by the receiving plant, not by the producer. Calciner injection tolerates coarser material than main burner injection, which requires fine, uniform particles for flame stability.

Densification raises bulk density and improves handling and storage stability but adds energy cost, and is justified where transport distance or storage duration require it.

Co-processing substitution rates

Thermal substitution rate is the proportion of thermal energy supplied by alternative fuel rather than conventional fossil fuel, and it is the metric cement operations manage.

Achievable rates differ sharply by injection point. Maximum thermal substitution rate through RDF is 80 to 100 per cent in the calciner, while it is limited to 50 to 60 per cent in the kiln burner [2].

The distinction reflects process requirements. The calciner operates at lower temperature with longer residence time and its function, calcining limestone, is tolerant of variable fuel characteristics. The main kiln burner must sustain a stable high-temperature flame producing the clinker mineralogy, which constrains fuel particle size, moisture, ash content and combustion rate.

Practical plant-level substitution rates are therefore a weighted average of the two injection points, and a plant claiming a high overall rate is generally achieving it through calciner substitution.

Why cement kilns are the preferred destination

Cement kilns offer technical advantages that dedicated combustion cannot match.

Gas residence time at temperatures above 1,400 degrees Celsius in the burning zone, with material residence far longer, ensures complete destruction of organic compounds including dioxin precursors.

The alkaline environment of the raw meal neutralises acid gases in situ, so hydrogen chloride and sulphur dioxide are absorbed rather than requiring downstream scrubbing.

Mineral constituents including ash and non-volatile metals are incorporated into the clinker mineral phase. There is no ash stream requiring separate disposal, which removes a cost that burdens dedicated incineration.

The counterweight is that clinker quality and kiln stability govern acceptance absolutely. A cement plant will refuse fuel that threatens either, irrespective of price.

Commercial structure and offtake risk

The RDF and SRF market is structurally asymmetric.

Fuel meeting a defined class specification, delivered consistently, commands a contract and a price or a favourable gate fee. Unspecified material competes against disposal alternatives and typically attracts a disposal cost.

Offtake concentration is the principal commercial exposure. A production plant sized around a single cement kiln has no alternative destination during kiln maintenance shutdowns, which in cement occur annually and last weeks. Storage capacity or a secondary offtake is therefore a design requirement, not a contingency.

Quality consistency is contractually enforced through sampling and testing regimes. Because EN 15359 classes are defined on statistical bases including medians and percentiles, the sampling protocol and frequency must be specified alongside the class, otherwise the classification cannot be demonstrated.

Application in the UAE and GCC

Three factors shape the regional position.

Cement production capacity across the GCC provides a substantial natural offtake for alternative fuel, and co-processing avoids the ash disposal burden that dedicated combustion carries in a region with limited hazardous waste disposal capacity.

Waste composition favours calorific value. High plastic content raises net calorific value, which improves NCV classification but simultaneously raises the chlorine risk where PVC is present, making PVC separation a higher priority here than in regions with lower plastic fractions.

Dedicated thermal capacity now competes for the same feedstock. Dubai’s Warsan facility processes up to 6,000 tonnes per day [4] and Abu Dhabi’s first waste-to-energy plant will process 900,000 tonnes annually from 2027 [5]. Mass burn plants accept unprocessed residual waste and therefore require no RDF production step, which means an RDF plant must justify its processing cost against a mass burn alternative that avoids it. Mass burn plants also pursue R1 recovery status under their own efficiency test rather than a fuel specification [8].

The defensible position for RDF production in this region is targeted: producing a specified high-calorific fuel for cement co-processing from commercial and industrial waste streams, rather than competing with mass burn for municipal residual waste.

Under UAE Federal Law No. 12 of 2018, Article 10 provides that usable secondary raw materials are not waste where usable in the same or another industry, which supports treating specified SRF as a product rather than a waste [7], while Article 11 requires municipal solid waste reduction and source separation [7]. Tadweer targets 80 per cent landfill diversion in Abu Dhabi by 2031 [5], and thermal routes carry a substantial share of that target for material recycling cannot take.



Frequently asked questions

What is the difference between RDF and SRF? SRF is produced to the EN 15359 specification, now ISO 21640, with a three-digit class code; RDF is the generic unspecified term [1].

What does SRF Class 3-2-2 mean? Net calorific value of at least 15 MJ/kg, total chlorine at or below 0.6 per cent (dry basis), and mercury at or below 0.03 mg/MJ median and 0.06 mg/MJ at the 80th percentile [1].

Why is chlorine the limiting parameter? It volatilises to alkali chlorides that corrode heat exchanger tubes and block preheater cyclones, causing unplanned kiln shutdowns [1].

How much fossil fuel can RDF replace in a cement plant? Between 80 and 100 per cent in the calciner but only 50 to 60 per cent in the main kiln burner [2].

What calorific value does real municipal RDF achieve? Field studies report averages of 14 to 22 MJ/kg, classifying NCV II to IV [3].


References

Show all 8 sources
  1. EN ISO 21640:2021 Solid recovered fuels — Specifications and classes (supersedes EN 15359:2011); class limits to be verified against the current edition. Supplementary commentary: MSW Sorting Machine. Understanding European Standard EN 15359 for Solid Recovered Fuel Specifications: An Engineering Compliance Framework. June 2026. Accessed: 7 September 2026.
  2. ResearchGate. RDF combustion versus gasification integration in the cement industry: thermal substitution rates. Accessed: 7 September 2026.
  3. Elsevier, Journal of Environmental Management. Evaluating opportunities of refuse derived fuel for energy-based industrial symbiosis towards a circular economy: a case study. March 2025. Accessed: 7 September 2026.
  4. Dubai Waste. Dubai Waste-to-Energy 2026: Warsan plant facts, capacity and Phase 2. 28 February 2026. Accessed: 7 September 2026.
  5. Khaleej Times. Abu Dhabi’s new waste-to-electricity plant to power 52,000 homes. 15 April 2026. Accessed: 7 September 2026.
  6. Evaluation of the potential of different high calorific waste fractions for the preparation of solid recovered fuels. Accessed: 7 September 2026.
  7. UAE Federal Law No. 12 of 2018 on Integrated Waste Management, Articles 10 and 11. Accessed: 7 September 2026.
  8. European Commission. Guidelines on the R1 energy efficiency formula in Annex II of Directive 2008/98/EC. Accessed: 7 September 2026.

About this article

Charmaine Frost is a landfill gas and waste-management specialist and a founding director of Qualifrost FZC LLC. Her experience was gained with major UK waste-management companies, covering landfill gas generation and collection systems, environmental monitoring and the practical risks of landfill operations. She holds the NEBOSH International General Certificate and has submitted her final NEBOSH Diploma assessment, with results expected in March–April 2027.

Reviewed by Adrian Frost, Director. Every article is checked against primary sources before publication: legal claims are verified against the instrument itself, and figures against the original dataset.

Published 25 August 2026 · Last reviewed 25 August 2026 · Next review August 2027, or sooner if the law changes.

Leave a Reply